Tempering furnace maintenance and maintenance

Special inspection by the fan of the front section 1. The temperature of the fan bearing housing should be checked every two hours, and the higher temperature rise should not exceed the ambient temperature of 40 °C.

2. The lubricating oil level should be in the upper and lower marking lines.

3, the fan and its system are not allowed to run with disease.

4. If the fan is found to have abnormal phenomena such as severe vibration, impact, and rapid rise in bearing temperature rise, emergency stop must be performed.

The second section of work per shift 1. Clean the surface of the equipment (including the operating console and the electric control cabinet), especially the photoelectric sensors and instrument glass should be clean and free of dust.

2. Check the fixed joints, especially the fixing screws of the fan, and the connection should be firm and reliable, not loose.

3. Check that the transmission chain and each transmission tape should be intact and the tightness is appropriate.

4, the equipment should run smoothly and normal, no abnormal sound, vibration and abnormal heat.

5. The work of various moving parts (such as wind dams, furnace doors, valves, etc.) should be flexible and free from sticking.

6. All electrical circuits and components should be intact, well connected and securely fastened. Check that the battery voltage should be normal (not less than 24V).

7. The connection (including soft connection) and fixing of each pipeline should be reliable, and there is no leakage.

8. The rubber roller and the rope roller should be intact and free from looseness and falling off.

9. When heating, observe the working condition of heating elements and fast fuses in each area, there should be no broken wire and short circuit; the furnace temperature should be even and stable (visual inspection should be no bright spots and dark areas).

10. Check that the connection between each encoder and its mounting shaft should be firm and reliable, not loose; the central axis of the encoder and the center line of the mounting shaft should maintain a high degree of coaxiality.

11. Check that the air switch wiring should be firm and free from overheating and odor.

12. Check that the fan current should be within the specified range when the fan valve is open.

13. Discharge the condensate from the pneumatic system (filter, cooler, dryer, etc.) and the oil level should be normal.